DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C1
*: Under development
SH11CR series are a family of fixed displacement motors, bent axis piston design for operation in both open and closed circuit. SH11CR
series motors are mainly intended for installation in mechanical gearboxes such as track drive and winches gear boxes.
The proven design incorporating the lens shape valve plate, the high quality components and manufacturing tecniques make the SH11CR
series motors able to provide up to 430 bar [6235 psi] continuos and 480 bar [6960 psi] peak performance.
Fully laboratory tested and field proven, these motors provide maximum efficiency and long life. Heavy duty bearings permit high radial
and axial loads.
Flangeable valves, both for open and closed circuit, enable SH11CR series motors to meet the requirements of the most different types
of applications.
Type
Displacement
cm
3
/rev [in
3
/rev]
Max. ow
l/min [U.S. gpm]
Max pressure
bar [psi]
Max peak pressure
bar [psi]
SH11CR 020
19.9 [1.213] 125 [33] 430 [6235] 480 [6960]
SH11CR 030
31.9 [1.945] 201 [53.06] 430 [6235] 480 [6960]
SH11CR 045*
46 [2.807] 257 [67.89] 430 [6235] 480 [6960]
SH11CR 055
56.35 [3.437] 282 [74.45] 430 [6235] 480 [6960]
SH11CR 063
63.26 [3.859] 316 [83.42] 430 [6235] 480 [6960]
SH11CR 075
77.82 [4.747] 350 [92.4] 430 [6235] 480 [6960]
SH11CR 090
86.23 [5.26] 388 [102.5] 430 [6235] 480 [6960]
SH11CR 108
108.4 [6.612] 433 [114.31] 430 [6235] 480 [6960]
SH11CR 125
124.8 [7.613] 500 [132] 430 [6235] 480 [6960]
SH11CR 160
163.9 [9.998] 590 [155.76] 430 [6235] 480 [6960]
SH11CR 180
178.1 [10.864] 641 [169.22] 430 [6235] 480 [6960]
Index
General information - Features .......................................... C2
Technical data .................................................................. C5
Ordering code .................................................................. C6
Dimensions 2 Bolts flange .............................................. C10
Other caratteristics ......................................................... C15
SH11CR - Fixed displacement motors for gearbox, plug in version
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C2
P1 P2 P3
General information - Features
Hydraulic uids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range at
operating temperature must be of 15 ÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed, for different
types of viscosity please contact Dana. Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷ 15 cSt is allowed for extreme
operating conditions and for short periods only.
Temperature ranges:
The operating temperature of the oil must be within -25ºC÷ 115ºC [-13ºF ÷ 239ºF]. For applications with lower temperatures please
contact Dana.
Filtering:
A correct filtering is essential for long and satisfactory life of axial piston units. In order to ensure a correct functioning of the unit, the max.
permissible contamination class is 21/19/16 according to ISO 4406:1999.
Operating pressure:
The maximum permissible pressure on pressure ports is 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak. If two motors are
connected in series, total working pressure P1+P2 has to be limited 700 bar max. [10150 psi].
Simbology:
C
N/bar
[lbf/psi]
Load
F
ax max
N
[lbf]
Axial pushing load
F
ax max
N
[lbf]
Axial pulling load
F
q
N
[lbf]
Radial load
F
q max
N
[lbf]
Maximum permissible radial load
J
kg·m
2
[lbf·ft
2
]
Moment of inertia
m
kg
[lbs]
Weight
n
max
rpm Maximum speed
p
max
bar
[psi]
Maximum continuous pressure
p
peak
bar
[psi]
Maximum pressure peak
Q
max
l/min
[U.S. gpm]
Maximum flow
q
d
l/min
[U.S. gpm]
External drain flow
T
k
Nm/bar
[lbf.ft/psi]
Torque costant
T
max
Nm
[lbf.ft]
Maximum torque at pressure continuous
T
peak
Nm
[lbf.ft]
Maximum torque at pressure peak
V
g
cm
3
/rev
[in
3
/rev]
Displacement
P
max
kW
[hp]
Maximum power at p
nom
η
hm
% Mech-hyd. efficiency
η
v
% Volumetric efficiency
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C3
bar
psi
p
n
rpm
0 1000 2000 3000 4000 5000 6000 7000
160-180 108-125
075-090
045-055-063
020-030
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
Case drain pressure:
The service life of the shaft seal is influenced by the speed of rotation of the motor and by case pressure. It’s recommended not to
exceed the value of 10 bar [145 psi], at reduced speed please see the diagram. Instantaneous pressure spikes (t<0.1 sec) up to 15 bar
[217.5 psi] are permitted.
General information - Features
Output shaft:
The service life of the shaft seal is influenced by the speed of rotation of the motor and by case pressure. It’s recommended not to exceed
the value of 10 bar [145 psi], at reduced speed please see the diagram. Instantaneous pressure spikes (t<0.1 sec) up to 15 bar [217.5
psi] are permitted.
Seals:
Seals used on standard SH11CR series axial piston motors are made by FKM seals (Fluoroelastomer). In case of use of special fluids,
contact Dana.
Minimum rotating speed:
No limit to Minimum speed; if uniformity of rotation is required, speed must not be less than 50 rpm. In case of use of special applications,
contact Dana.
Installation:
SH11CR motors can be installed in various position and directions; however, installation in vertical position with shaft towards upper is
not allowed. These axial piston units have separated ports and drain chambers and so must be always drained. For further detail see at
General installation guidelines.
Speed
Pressure
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C4
General information - Features
Flangeable valves:
Flangeable valves are available for motors both in open and closed loop. For more information see the catalogue Axial Valves.
Flushing valves:
The motors can be equipped with flushing valves.
The mount the flushing valve on motors, it is necessary to use a special port cover. For more information see the catalogue Axial Valves.
Relation between direction of rotation and direction of ow:
The relation between direction of rotation of shaft and direction of flow in SH11CR piston units is shown in the picture below.
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C5
* : under development
Technical data
Theorical values, without considering η
hm
and η
v
approximate values. Peak operations must not exceed 1% of every minute. A
simultaneous maximum pressure and maximum speed not recommended.
Notes:
1) Approximate values.
2) Average values at 250 bar [3625 psi] with mineral oil at 45°C [113°F] and 35 cSt of viscosity.
Size
020 030 045* 055 063 075 090 108 125 160 180
Displacement V
g
cm
3
/rev
[in
3
/rev]
19.9
[1.213]
31.9
[1.945]
46
[2.807]
56.35
[3.437]
63.26
[3.859]
77.82
[4.747]
86.23
[5.26]
108.4
[6.612]
124.8
[7.613]
163.9
[9.998]
178.1
[10.864]
Max. pressure p
max
bar
[psi]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
430
[6235]
Max. peak pressure p
peak
bar
[psi]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
480
[6960]
Max. speed n
max
rpm 6300 6300 5600 5000 5000 4500 4500 4000 4000 3600 3600
Max. ow Q
max
l/min
[US gpm]
125
[33]
201
[53.06]
257
[67.89]
282
[74.45]
316
[83.42]
350
[92.4]
388
[102.5]
433
[114.31]
500
[132]
590
[155.76]
641
[169.22]
Max. power at p
max
P
max
kW
[hp]
90
[120.6]
144
[192.96]
184
[246.7]
202
[270.68]
226
[302.84]
251
[336.34]
278
[372]
310
[415.4]
358
[479.72]
423
[566.82]
459
[615.06]
Torque costant T
k
Nm/bar
[lbf.ft/psi]
0.3
[0.015]
0.5
[0.025]
0.73
[0.037]
0.9
[0.045]
1
[0.05]
1.2
[0.06]
1.4
[0.07]
1.7
[0.085]
2
[0.1]
2.6
[0.13]
2.8
[0.14]
Max.
cont.
torque at p
max
T
max
Nm
[lbf.ft]
136
[100.23]
218
[160.66]
315
[232.33]
386
[284.48]
433
[319.12]
533
[392.82]
590
[435.13]
742
[546.85]
855
[630.13]
1122
[826.91]
1219
[898.40]
Max peak torque at p
peak
T
peak
Nm
[lbf.ft]
152
[112.02]
244
[179.82]
352
[260.36]
431
[317.65]
484
[356.71]
595
[438.51]
659
[486.05]
829
[610.97]
954
[703.10]
1253
[923.46]
1361
[1003.06]
Moment of inertia
(2)
J
kg·m
2
[lbf.ft
2
]
0.001
[0.0235]
0.001
[0.0235]
0.004
[0.094]
0.004
[0.094]
0.004
[0.094]
0.007
[0.1645]
0.007
[0.1645]
0.012
[0.2820]
0.012
[0.2820]
0.022
[0.5170]
0.022
[0.5170]
Weight
(2)
m
kg
[lbs]
10
[22.04]
10
[22.04]
18
[39.68]
19
[41.876]
19
[41.876]
23.7
[52.23]
23.7
[52.23]
35
[77.14]
35
[77.14]
48
[105.79]
48
[105.79]
External drain ow
(2)
Q
d
l/min
[US gpm]
1
[0.264]
1
[0.264]
1.2
[0.317]
1.2
[0.317]
1.2
[0.317]
2.5
[0.66]
2.5
[0.66]
3
[0.79]
3
[0.79]
3
[0.79]
3
[0.79]
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C6
The following alphanumeric codes system has been developed to identify all of the configuration options for the SH11CR series. Use the
model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Series
Motor
Size
Version
Mount ange
Shaft end
Port cover
Direction of
rotation
Seal
Valve
Valve feature
Flushing valve
Special feature
Painting
SH11CR M 030 GE OH SAG VM2 RV V VCDM 000 06 RD 01
Ordering code
1
Series
SH11CR
Fixed displacement, bent axis, axial piston unit
3
Size
020
20 cm
3
/rev [1.22 in
3
/rev]
030
30 cm
3
/rev [1.83 in
3
/rev]
045*
46 cm
3
/rev [2.807in
3
/rev]
055
55 cm
3
/rev [3.355 in
3
/rev]
063
63 cm
3
/rev [3.843 in
3
/rev]
075
75 cm
3
/rev [4.575 in
3
/rev]
090
90 cm
3
/rev [5.49 in
3
/rev]
108
108 cm
3
/rev [6.588 in
3
/rev]
125
125 cm
3
/rev [7.625 in
3
/rev]
160
160 cm
3
/rev [9.76 in
3
/rev]
180
180 cm
3
/rev [10.98 in
3
/rev]
4
Version
GE
ISO 3019-2 metric
2
Motor
M
Motor
* : under development
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
SH11CR M 030 GE OH SAG VM2 RV V VCDM 000 06 RD 01
Ordering code
* : under development
5
Mount Flange
Size
020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
OH
2 holes Ø 135 mm [Ø 5.315 in]
OL
2 holes Ø 160 mm [Ø 6.299 in]
OM
2 holes Ø 190 mm [Ø 7.480 in]
ON
2 holes Ø 200 mm [Ø 7.874 in]
• : Available
* : under development
• : Available
6
Shaft end
Size
020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
SAG
Splined W25x1.25x18x9g DIN 5480
SAI
Splined W30x2x14x9g DIN 5480
SAM
Splined W35x2x16x9g DIN 5480
SAO
Splined W40x2x18x9g DIN 5480
SAP
Splined W45x2x21x9g DIN 5480
SAR
Splined W50x2x24x9g DIN 5480
8
Direction of rotation (viewed from shaft side)
RV
Reversible
7
Port cover
Size
020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
VM2
Lateral ports same side
LM2
Lateral ports same side
FM2
Frontal ports (only 055-063 displacements)
9
Seal
V
FKM
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C8
1 2 3 4 5 6 7 8 9 10 11 12 13 14
SH11CR M 030 GE OH SAG VM2 RV V VCDM 000 06 RD 01
Ordering code
10
Valve
Size
020 - 030 045 - 055* - 063 075 - 090 108 - 125 160 - 180
XXXX
None
VCDM
VCD/M Pilot assisted overcentre valve
VM2 VM2–FM2 VM2 VM2 VM2
VCD1
VCD/1 Pilot assisted overcentre valve
LM2 LM2 LM2 LM2
VCD2
VCD/2 Pilot assisted overcentre valve
LM2 LM2 LM2
VCR1
VCR1 D/AF Double acting overcentre valve
VM2
VCR3
VCR3 Double acting overcentre valve
VM2 VM2 VM2 VM2
* : under development
• : Available
1) The VM2 digit means that the valve is only available with VM2 port cover.
2) The LM2 digit means that the valve is only available with LM2 port cover.
11
Valve feature
Valve
XXXX VCDM VCD1 VCD2 VCR1 VCR3
000
Feature not necessary
001
Not Set 30÷350 bar [435 to 5075 psi]
(Piloting ratio 6.2:1)
002
Not Set 0÷350 bar [0 to 5075 psi]
(Piloting ratio 2.9:1)
Control of rotation CW
006
Not Set 0÷350 bar [0 to 5075 psi]
(Piloting ratio 2.9:1)
Control of rotation CCW
004
Not Set 30÷350 bar [435 to 5075 psi]
(Piloting ratio 6.2:1)
Control of rotation CW
005
Not Set 30÷350 bar [435 to 5075 psi]
(Piloting ratio 6.2:1)
Control of rotation CCW
(1)
003
Not Set 250÷500 bar [3625 to 7250 psi]
(Piloting ratio 13:1)
Control of rotation CW
007
Not Set 250÷500 bar [3625 to 7250 psi]
(Piloting ratio 13:1)
Control of rotation CCW
• : Available
1) : Available with FM2 port cover
Please contact Technical department for valve which requie specific setting.
For the technical specifications see catalogue valves.
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C9
1 2 3 4 5 6 7 8 9 10 11 12 13 14
SH11CR M 030 GE OH SAG VM2 RV V VCDM 000 06 RD 01
Ordering code
14
Painting
XX
None
01
Painted RAL 9005
02
Painted RAL 5015
12
Flushing valve
XX
None
PR
Arranged for Flushing Valve
LM2
06
VSC/F Flushing valve - 6 l/min [1.58 U.S. gpm]
LM2-VM2
09
VSC/F Flushing valve - 10.5 l/min [2.77 U.S. gpm]
LM2-VM2
15
VSC/F Flushing valve - 15 l/min [3.96 U.S. gpm]
LM2-VM2
It is not possible to combine the flushing valves with valve on table 10.
For the technical specifications see catalogue valves.
1) The LM2-VM2 digit means that the valve is only available with LM2 and VM2 port cover.
• : Available
13
Special feature
XX
None
RD
Drain plugs reversed
TS
Prepared for tachometer sensor
TZ
Tachometer + sensor 2-channel-Hall effect
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C10
SH11CR 020-030
87.1 [3.43]
15 [0.59]
15 [0.59]
72.8 [2.866]
187.5 [0.74]
160 [6.30]
OR 2-250
S2
S1
Ø135 h6 [5.31]
Ø94 [3.70]
92 [3.622]
Ø14 [0.55]
71 [2.80]
80 [3.15]
13.7 [0.539]
40°
VM2
LM2
115 [4.53]
59 [2.32]
40.49 [1.594]
119.9 [4.72]
95.2 [3.75]
1/2” SAE 6000
1/2” SAE 6000
M8 Depth 18 [0.708]
18.24 [0.718]
90.2 [3.55]
C
A
B
C
127.3 [5.01]
88.2 [3.47]
119 [4.69]
1/2” SAE 60001/2” SAE 6000
108.9 [4.29]
40.49 [1.594]
18.24 [0.718]
69.7 [2.75]
M8
30 [1.18]
22 [0.87]
123.8 [4.87]
88.8 [3.50]
Profilo / Spline
W30x2x30x14x9g DIN 5480
M10
Ø29.6 [1.17]
88.9 [3.50]
22 [0.87]
121.9 [4.80]
28 [1.10]
Profilo / Spline
W25x1.25x30x18x9g DIN 5480
M8
Ø24.8 [0.976]
Dimensions 2 Bolts ange
7
Port cover
S1, S2: Drain ports (1 plugged) - 3/8 G (BSPP)
A, B: Service line ports
6
Shaft end
SAG
Splined
shaft
Detail C
Detail C
SplineSpline
SAI
Splined
shaft
(OH)
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C11
SH11CR 045-055-063
VM2
LM2
90 [3.54]
15 [0.59]
18.8 [0.74]
OR 2-258
S2
S1
83 [3.267]
234.3 [9.22]
200 [7.874]
104 [4.094]
20.5 [0.807]
18 [0.71]
96.5 [3.80] 82 [3.23]
Ø160 [6.299 ]
0
-0.025
0
-0.0009
Ø121 [4.76]
40°
147 [5.79]
75 [2.953]
50.8 [2.00]
144.7 [5.69]
116.5 [4.59]
3/4” SAE 6000 3/4” SAE 6000
M10 Depth 18 [0.708]
23.8 [0.937]
111.1 [4.37]
C
A
B
C
155 [6.10]
108.5 [4.271]
147 [5.79]
A
B
3/4” SAE 6000
3/4” SAE 6000
137.8 [5.43]
50.8 [2.00]
23.8 [0.937]
88.4 [3.48]
M10 Depth 18 [0.708]
Ø19 [0.748]
Ø19 [0.748]
Visto da C/Detail C
24 [0.94]
22 [0.87]
127.3 [5.01]
92.3 [3.63]
Spline
W30x2x30x14x9g DIN 5480
M10
Ø29.6 [1.17]
132.3 [5.21]
92.3 [3.63]
32 [1.26]
28 [1.10]
Spline
W35x2x30x16x9g DIN 5480
Ø34.5 [1.36]
M12
Dimensions 2 Bolts ange (OL)
S1, S2: Drain ports - 1/2 G (BSPP)
A, B: Service line ports
7
Port cover
6
Shaft end
Detail C
Detail C
SAI
Splined
shaft
SAM
Splined
shaft
Maximum working pressure for 063 displacement: 300 bar [4350
psi]
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C12
147.6 [5.81]
114.4 [4.503]
84 [3.307]
57.15 [2.25]
1” SAE 6000
1” SAE 6000
M12 Depth 19 [0.748]
27.76 [1.093]
122.7 [4.83]
A
B
VM2
LM2
SH11CR 075-090
106 [4.17]
15 [0.59]
82 [3.23]
17.1 [0.67]
259 [10.20]
224 [8.82]
OR 2-262
S2
S1
Ø140.3 [5.52]
13.9 [0.55]
22 [0.87]
110 [4.33]
97.7 [3.85]
121 [4.76]
40°
Ø190 [7.48 ]
0
-0.029
0
-0.0011
154.8 [6.09]
105.3 [4.146]
166 [6.54]
1” SAE 6000
1” SAE 6000
M12 Depth 18 [0.708]
148.5 [5.85]
95.1 [3.744]
A
B
57.15 [2.25]
27.76 [1.093]
Ø25 [0.98]
Ø25 [0.98]
C
110 [4.33]
150 [5.905]
32 [1.26]
28 [1.10]
Spline
W35x2x30x16x9g DIN 5480
M12
Ø34.2 [1.34]
110 [4.33]
155 [6.10]
37 [1.45]
36 [1.42]
Spline
W40x2x30x18x9g DIN 5480
M16
39.5 [1.55]
S1, S2: Drain ports - 1/2 G (BSPP)
A, B: Service line ports
7
Port cover
6
Shaft end
Dimensions 2 Bolts ange (OM)
SAM
Splined
shaft
Detail C
Detail C
Maximum working pressure for 090displacement: 300 bar [4350 psi]
SAO
Splined
shaft
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C13
1”1/4” SAE 6000 1”1/4 SAE 6000
C
183.3 [7.22]
130.3 [5.129]
194 [7.64]
A
B
166.2 [6.54]
111.9 [4.405]
66.68 [2.625]
31.75 [1.25]
M14 Depth 25 [0.984]
Ø32 [1.26]
Ø32 [1.26]
SH11CR 108-125
VM2
LM2
286 [11.26]
250 [9.842]
101 [3.976]
119 [4.69]
15 [0.59]
19.6 [0.771]
OR 2-264
S1
S2
103 [4.06]
116 [4.57]
22 [0.87]
15 [0.59]
125 [4.921]
152.3 [6.00]
40°
Ø200 [7.874 ]
0
-0.029
0
-0.0011
37.4 [1.47]
23 [0.91]
167.5 [6.60]
122.5 [4.82]
Spline
W40x2x30x18x9g DIN 5480
M12
Ø39.6 [1.56]
172.5 [6.79]
122.5 [4.82]
42 [1.65]
36 [1.41]
Spline
W45x2x30x21x9g DIN 5480
Ø44.5 [1.75]
M16
194 [7.64]
99 [3.897]
66.68 [2.625]
179.4 [7.06]
143 [5.629]
1”1/4” SAE 6000 1”1/4 SAE 6000
M14 Depth 19 [0.748]
31.75 [1.25]
135.7 [5.342]
159.8 [6.29]
A
B
Dimensions 2 Bolts ange (ON)
S1, S2: Drain ports (1 plugged) - 1/2 G (BSPP)
A, B: Service line ports
R: Air bleed (plugged) - 1/8 G (BSPP)
7
Port cover
6
Shaft end
Detail C
Detail C
SAO
Splined
shaft
Maximum working pressure for 125 displacement: 300 bar [4350 psi]
SAP
Splined
shaft
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C14
1”1/4” SAE 6000
1”1/4 SAE 6000
C
210.9 [8.30]
153.7 [6.051]
202 [7.95]
A
B
191.4 [7.54]
129.8 [5.11]
66.68 [2.625]
31.75 [1.25]
M14 Depth 25 [0.984]
Ø32 [1.26]
Ø32 [1.26]
194 [7.64]
99 [3.897]
66.68 [2.625]
202.9 [7.99]
156.9 [6.177]
1”1/4 SAE 6000 1”1/4 SAE 6000
M14 Depth 19 [0.748]
31.75 [1.25]
149.2 [5.874]
186 [7.32]
A
C
B
SH11CR 160-180
VM2
LM2
CAK
Parallel
keyed shaft
13.2 [0.519]
23 [0.905]
117.1 [4.61]
119 [4.70]
15 [0.59]
OR 2-264
S1
S2
104 [4.09]
116 [4.57]
147 [5.787]
171.6 [6.76]
Ø200 [7.874 ]
0
-0.029
0
-0.0011
286 [11.26]
250 [9.842]
Ø22 [0.87]
42 [1.65]
36 [1.41]
172.8 [6.80]
122.8 [4.83]
Profilo / Spline
W45x2x30x21x9g DIN 5480
M16
Ø44.5 [1.75]
177.8 [7.00]
122.8 [4.83]
44 [1.73]
36 [1.41]
Profilo / Spline
W50x2x30x24x9g DIN 5480
Ø48.8 [1.96]
M16
SAP
Splined
shaft
Dimensions 2 Bolts ange (ON)
S1, S2: Drain ports (1 plugged) - 1/2 G (BSPP)
A, B: Service line ports
R: Air bleed (plugged) - 1/8 G (BSPP)
7
Port cover
6
Shaft end
Detail C
Detail C
Spline
Spline
Maximum working pressure for 180 displacement: 300 bar [4350 psi]
SAR
Splined
shaft
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C15
B
A
D
C
B
A
7 + 12
Flushing valve version and port cover “LM2”
Flushing valve Arranged for ushing valve
020 045-055 075 108 160
030 063 090 125 180
A
mm
[in]
LM2
161
[6.33]
245.7
[9.67]
259.4
[10.21]
294.3
[11.58]
319.6
[12.58]
B
mm
[in]
LM2
130
[5.12]
152.8
[6.01]
159.1
[6.26]
179.9
[7.08]
199.1
[7.84]
C
mm
[in]
LM2
140
[5.51]
225.7
[8.88]
239.4
[9.42]
274.3
[10.79]
299.6
[11.79]
D
mm
[in]
LM2
120
[4.72]
142.8
[5.62]
149.1
[5.87]
169.9
[6.68]
189.1
[7.44]
7 + 12
Flushing valve version and port cover “VM2”
020 045-055 075 108 160
030 063 090 125 180
A
mm
[in]
VM2
148
[5.82]
178
[7.01]
181
[7.12]
216.5
[8.52]
223.4
[8.79]
B
mm
[in]
VM2
173
[6.81]
194
[7.64]
205
[8.07]
218
[8.58]
231.7
[9.12]
Other caratteristics
Click Dana button to return to Section indexClick i button to return to main index
i
C16
DC5A1G1_0000000R2 - 01/24
SH11CR/M - Section C
Other caratteristics
13
Version with tachometer and “TZ” sensor
020 045-055 075 108 160
030 063 090 125 180
A
mm
[in]
58
[2.28]
77
[3.03]
76
[2.99]
86
[3.39]
93.5
[36.81]
B
mm
[in]
15
[0.59]
32
[1.26]
11
[0.43]
25
[0.98]
26.5
[1.04]
A
B
30°
TZ: With tachometer. Supplied with phonic wheel
and sensor.
2-Channel differential-hall effect operating principle Sensor
with dual-channel output (90°)
Power supply 8-32 VDC
Frequency 0-20.000 Hz
Operating temperature -40°C +125°C
Degree of protection IP67
Sensor connector Deutsch DT04-4P
Electromagnetic compatibility according to EN 60947-5-2
Resistence to schock and vibration in accordance with IEC
68-2-17 IEC 68-2-6
Size
020 045-055 075 108 160
030 063 090 125 180
Number of pulses per revolution
38 47 53 59 67
Click DANA button to return to Section Index Click i button to return to main index
i
DC5A1G1_0000000R2 - 03/24
SH11CR/M - Section C
C17
S1
S2
S1
S2
For the SH11CR motors it is possible to request the drain plug reversed compared to standard.
If it is necessary the motor with this configuration, to specify in the purchase order the value “RD” (See position 13 of ordering code).
STANDARD VERSION “RD” VERSION
S1 - Metallic plug.
S2 - Plastic plug.
S1 - Plastic plug.
S2 - Metallic plug.
13
Drain plug reversed “RD”
Other caratteristics
Click Dana button to return to Section indexClick i button to return to main index
i
DC5A1G1_0000000R2 - 01/24
SH11CR/M - Section C
Click DANA button to return to Section Index Click i button to return to main index
i